Fluke 572-2 infrahőmérő

  • Méréstartomány: -30 °C – 900 °C
  • Optikai arány: 60:1 kettős lézer célzással
  • Minimum, maximum, differenciál, átlag mérési funkciók
  • K-típusú hőelem csatlakoztatási lehetőség
  • Állítható emissziós tényező
  • Alacsony és magas hőmérséklet riasztás
  • Adatrögzítés 99 adatkészletre
  • Fotóállvány rögzítési lehetőség
  • FlukeView® Forms dokumentáló szoftver, USB 2.0 kimenet

Leírás

Infrared Measurements
Infrared temperature range -30°C to 900°C (-22°F to 1652°F)
IR accuracy (calibration geometry with ambient temperature 23°C ± 2°C) ≥ 0°C: ± 1°C or ± 1% of the reading, whichever is greater
≥ -10°C to < 0°C: ±2°C
< -10°C: ±3°C
≥ 32°F: ± 2°F or ± 1% of the reading, whichever is greater
≥ 14°F to < 32°F: ±4°F
< 14°F: ±6°F
IR repeatability ±0.5% of reading or ±0.5°C (±1°F), whichever is greater
Display resolution 0.1°C / 0.1°F
Distance: Spot 60:1 (calculated at 90% energy)
Minimum spot size 19 mm
Laser sighting Offset dual laser, output < 1 mW
Spectral response 8 μm to 14 μm
Response time (95%) < 500 ms
Emissivity Digitally adjustable from 0.10 to 1.00 by 0.01 or via built-in table of common materials
Contact Measurements
K-type thermocouple input temperature range -270°C to 1372°C (-454°F to 2501°F)
K-type thermocouple input accuracy (with ambient temperature 23°C ± 2°C) < -40°C: ±(1°C + 0.2° / 1°C)
≥ -40°C: ±1% or 1°C, whichever is greater
< -40°F: ±(2°F + 0.2° / 1°F)
≥ -40°F: ±1% or 2°F, whichever is greater
K-type thermocouple 0.1°C / 0.1°F
K-type thermocouple repeatability ±0.5% of reading or ±0.5°C (±1°F), whichever is greater
Measurement Options
Hi/Low alarms Audible and two-color visual
Min/Max/Avg/Dif Yes
Switchable celsius and fahrenheit Yes
Backlight Two levels, normal and extra bright for darker environments
Probe input K-type thermocouple simultaneous display of probe and IR temperature
Trigger lock Yes
Data storage 99 points
Display Dot matrix 98 x 96 pixels with function menus
Communication USB 2.0
K-Type Thermocouple Specifications
Measurement range (bead probe) -40°C to 260°C (-40°F to 500°F)
Accuracy ±1.1°C (±2.0°F) from 0°C to 260°C (32°F to 500°F). Typically within 1.1°C (2.0°F) from -40°C to 0°C (-40°F to 32°F)
Cable length 1 m (40 in) K-type thermocouple cable with standard miniature thermocouple connector and bead termination
General Specifications
Safety and compliance IEC 60825-1
FDA Laser Class II
IEC 61326-1
CE Complaint
CMC # 01120009
Operating temperature 0°C to 50°C (32°F to 122°F)
Storage temperature -20°C to 60°C (-4°F to 140°F)
Relative humidity 10% to 90% RH non-condensing up to 30°C (86°F)
Operating altitude 2000 meters above mean sea level
Weight 0.322 kg (0.7099 lb)
Power 2 AA batteries
Battery life 8 hours with laser and backlight on; 100 hours with laser and backlight off, at 100% duty cycle (thermometer continuously on)

Ajánlatkérés

Célunk, hogy minél egyszerűbbé tegyük  az Ön számára az ajánlatkérést.

Kérjük, töltse ki az alábbi űrlapot és küldje el.

Kollégáink hamarosan jelentkezni fognak az ajánlattal.

Ajánlatkérés

Telefonos visszahívás kérése

Célunk, hogy minél egyszerűbbé tegyük  az Ön számára a termékeinkkel kapcsolatos információhoz jutást.

Kérjük, töltse ki az alábbi űrlapot és küldje el.

Kollégáink hamarosan jelentkezni fognak, hogy megválaszolják kérdését.

Telefonos visszahívás

Videó

Specifikáció

Letölthető termék információ:  Fluke 572-2