Leírás
-
Specifications (Check the Fluke web for detailed specifications) Test voltage (dc) Range Accuracy (± reading) 250 V < 200 kΩ unspecified 200 kΩ to 5 GΩ 5 % 5 GΩ to 50 GΩ 20 % > 50 GΩ unspecified 500 V < 200 kΩ unspecified 200 kΩ to 10 GΩ 5 % 10 GΩ to 100 GΩ 20 % > 100 GΩ unspecified 1000 V < 200 kΩ unspecified 200 kΩ to 20 GΩ 5 % 20 GΩ to 200 GΩ 20 % > 200 GΩ unspecified 2500 V < 200 kΩ unspecified 200 kΩ to 50 GΩ 5 % 50 GΩ to 500 GΩ 20 % > 500 GΩ unspecified 5000 V < 200 kΩ unspecified 200 kΩ to 100 GΩ 5 % 100 GΩ to 1 TΩ 20 % > 1 TΩ unspecified 10000 V < 200 kΩ unspecified 200 kΩ to 200 GΩ 5 % 200 GΩ to 2 TΩ 20 % > 2 TΩ unspecified Bar Graph Range 0 to 1 TΩ Insulation test voltage accuracy -0 %, +10 % at 1 mA load current Induced ac mains current rejection 2 mA maximum Charging rate for capacitive load 5 seconds per μF Discharge rate for capacitive load 1,5 s/μF Range Accuracy Leakage current measurement 1 nA to 2 mA ± (5% + 2 nA) Capacitance measurement 0,01 uF to 15,00 μF ± (15% rdg + 0,03 μF) Timer Range Resolution 0 to 99 minutes Setting: 1 minute Indication: 1 second Live circuit warning Warning range Voltage accuracy 30 V to 660 V ac/dc, 50/60 Hz ± (15% + 2 V) Temperature (operating): Enclosure sealing: IP40 -20 °C to 50 °C ( -4 °F to 122 °F) Altitude: 0 to 2000 m Temperature (storage): Power: 12 V lead-acid rechargeable battery, -20 °C to 65 °C (-4 °F a 149 °F) Yuasa NP2.8-12 Humidity: 80 % to 31 ºC decreasing linearly to Dimensions: 170 mm x 242 mm x 330 mm 50 % at 50 ºC Weight: 3,6 kg (7,94 lb) 3-year warranty