Fluke 345 hálózat analizáló lakatfogó

  • Magas biztonsági kategória 600V CAT IV / 1000V CAT III
  • AC / DC árammérés 2000A-ig
  • Harmonikus analízis a 30-adik harmonikusig (15Hz – 22Hz között a 40-edik harmonikusig)
  • Akkumulátor ellenőrzés: DC hullámzás direkt mérése akkumulátoroknál és DC rendszereknél

Leírás

  • Specifications
    Display Color transmissive LCD 320 x 240 pixels (70 mm diagonal) with 2 level backlight
    Power supply Battery type 1.5 V Alkaline AA MN 1500 or IEC LR6 x 6
    Battery life typically > 10 hours (backlight on full)
    > 12 hours (backlight reduced)
    Battery eliminator Input 110/230 V 50/60 Hz
    Output 15 VDC, 300 mA
    Ambient conditions (for indoor use only)
    Reference conditions All accuracies stated at 23°C ±1°C (73.4°F ±1.8°F)
    Operating temperature 0°C to 50°C (32°F to 122°F)
    Temperature coefficient of current ≤ ±0.15% of rdg per °C
    Temperature coefficient of voltage ≤ ±0.15% of rdg per °C
    Maximum relative humidity 80% for temperatures up to 31°C (87°F) decreasing linearly to 50% relative humidity at 40°C (104°F)
    Maximum operating altitude 2000 m
    Electrical safety
    Maximum safe working voltages Safety IEC 61010-1 600 V CAT IV double or reinforced insulation, pollution degree 2
    Protection IP40; EN60529
    Current measurement 600 VAC rms or DC between uninsulated conductor and ground
    Voltage measurement 600 VAC rms or DC between either input terminal and ground, or 825 V between energized phase voltages (delta power config.)
    EMC
    Emission IEC/EN 61326-1:1997 A
    Immunity IEC/EN 61326-1:1997 Annex C Performance Criterion B
    Mechanical
    Dimensions (L x W x D) 300 x 98 x 52 mm (12 x 3.75 x 2 in)
    Weight including batteries 820 g (1.8 lb)
    Jaw opening 60 mm
    Jaw capacity 58 mm diameter
    Cleaning The unit can be cleaned with an Isopropanol impregnated cloth. Do not use abrasives or other solvents.
    Electrical data
    Accuracy 23°C ±1°C (73.4°F ±1.8°F). See Ambient conditions specifications for temperature coefficients.
    Current measurement (DC, DC rms, AC rms)
    Measuring range 0 to 2000 A DC or 1400 AC rms
    Autorange facility 40 A / 400 A / 2000 A
    Resolution 10 mA in 40 A range
    100 mA in 400 A range
    A in 2000 A range
    Accuracy: DC and DC rms I > 10 A ±1.5% rdg ±5 digits
    I < 10 A ±0.2 A
    Accuracy: AVG I > 10 A ±3% rdg ±5 digits
    I < 10 A ±0.5 A
    Accuracy: Pk I > 10 A ±5% rdg ±5 digits
    I < 10 A ±0.5 A
    Accuracy: AHr I > 10 A ±2% rdg ±5 digits
    I < 10 A ±0.5 AHr
    Accuracy: CF (Crest Factor) 1.1 ≤ CF < 3 ±3% rdg ±5 digits
    3 ≤ CF < 5 ±5% rdg ±5 digits
    Resolution 0.01
    Accuracy: RPL (Ripple) 2% ≤ RPL < 100%  ±3% rdg ±5 digits
    100% ≤ RPL < 600% ±5% rdg ±5 digits
    Resolution 0.1%
    I DC > 5 A, I AC > 2 A
    All measurements DC and 15 Hz to 1 kHz
    Maximum overload 10,000 A or rms x frequency < 400,000
    Amps rms is a true-rms measurement (AC + DC)
    Voltage measurement (DC, DC rms, AC rms)
    Measuring range 0 to 825 VDC or AC rms
    Autorange facility 4 V / 40 V / 400 V / 750 V
    Resolution 1 mV in 4 V range
    10 mV in 40 V range
    100 mV in 400 V range
    1 V in 750 V range
    Accuracy: DC and DC rms V > 1 V ±1% rdg ±5 digits
    V < 1 V ±0.02 V
    Accuracy: AVG V > 1 V ±3% rdg ±5 digits
    V < 1 V ±0.03 V
    Accuracy: Pk V > 1 V ±5% rdg ±5 digits
    V < 1 V ±0.03 V
    Accuracy: CF (Crest Factor) 1.1 ≤ CF < 3 ±3% rdg ±5 digits
    3 ≤ CF < 5 ±5% rdg ±5 digits
    Resolution 0.01
    Accuracy: RPL (Ripple) 2% ≤ RPL < 100% ±3% rdg ±5 digits
    100% ≤ RPL < 600% ±5% rdg ±5 digits
    Resolution 0.1%
    VDC > 0.5 V, VAC > 0.2 V
    All measurements DC and 15 Hz to 1 kHz
    Maximum overload 1,000 V rms
    Volts rms is a true-rms measurement (AC + DC)
    Harmonics
    THD (Total Harmonic Distortion) 1% ≤ THD < 100% ±3% rdg ±5 digits
    100% ≤ THD < 600% ±5% rdg ±5 digits
    Resolution 0.1%
    DF (Distortion Factor) 1% ≤ DF < 100% ±3% rdg ±5 digits
    Resolution 0.1%
    H02 ≤ Vharm < H13 ±5% ±2 digits
    H13 ≤ Vharm ≤ H30 ±10% ±2 digits
    All measurements up to 30th harmonic (40th harmonic for 15 Hz to 22 Hz)
    Frequency range of fundamental F0 15 Hz to 22 Hz and 45 Hz to 65 Hz
    Vacrms > 1V
    Watts measurement (single and three-phase) (DC, DC rms, AC rms)
    Measuring range 0 to 1650 kW DC or 1200 kW AC
    Measuring range 4 kW, 40 kW, 400 kW, 1650 kW
    Resolution 1 W in 4 kW
    10 W in 40 kW
    100 W in 400 kW
    1 kW in 1200 kW
    Accuracy 2.5% rdg ±5 digits
    W1Ø < 2 kW ±0.08 kW
    W3Ø < 4 kW ±0.25 kW
    VA measurement (single- and three-phase) (DC, DC rms, AC rms)
    Measuring range 0 to 1650 kVA DC or 1200 kVA AC
    Autorange facility 4 kVA, 40 kVA, 400 kVA, 1650 kVA
    Resolution 1 VA in 4 kVA
    10 VA in 40 kVA
    100 VA in 400 kVA
    1 kVA in 1200 kVA
    Accuracy VA > 2 kVA 2.5% rdg ±5 digits
    VA < 2 kVA ±0.08 kVA
    VAR measurement (single- and three-phase)
    Measuring range 0 to 1250 kVAR
    Autorange facility 4 kVAR, 40 kVAR, 400 kVAR, 1200 kVAR
    Resolution 1 VAR in 4 kVAR
    10 VAR in 40 kVAR
    100 VAR in 400 kVAR
    1 kVAR in 1200 kVAR
    Accuracy VAR > 4 kVAR ±2.5% rdg ±5 digits
    VAR < 4 kVAR ±0.25 kVAR
    Power factor range 0.3 < PF < 0.99
    Power factor (single- and three-phase)
    Measuring range 0.3 capacitive to 1.0 and 1.0 to 0.3 inductive (72.5° capacitive to 0° and 0° to 72.5° inductive)
    Resolution 0.001
    Accuracy ±3°
    Frequency range 15 Hz to 1 kHz
    Displacement power factor (single- and three-phase)
    Measuring range 0.3 capacitive to 1.0 and 1.0 to 0.3 inductive (72.5° capacitive to 0° and 0° to 72.5° inductive)
    Resolution 0.001
    Accuracy ±3°
    Frequency range 15 Hz to 22 Hz and 45 Hz to 65 Hz
    Kilowatt hour (kWHr)
    Measuring range 40,000 kWHr
    Autorange facility 4 kWHr, 40 kWHr, 400 kWHr, 4,000 kWHr, 40,000 kWHr
    Resolution 1 WHr in 4 kWHr Range
    10 WHr in 40 kWHr Range
    100 WHr in 400 kWHr Range
    1 kWHr in 4,000 kWHr Range
    10 kWHr in 40,000 kWHr Range
    Accuracy kWHr > 2 kWHr ±3% ±5 digits
    kWHr < 2 kWHr ±0.08 kWHr
    All Watts /VA /VAR /PF measurements Frequency range DC and 15 Hz to 1 kHz
    Current range 10 A to 1400 A rms
    Voltage range 1 V to 825 V rms
    Maximum input 825 V rms / 1400 A rms
    Maximum overload 1000 V rms / 10,000 A All measurements DC and 15 Hz to 1 kHz. Maximum overload 10,000 A or rms x frequency < 400,000
    Frequency measurement (from current or voltage sources)
    Measuring range 15 Hz to 1 kHz
    Resolution 0.1 Hz
    Accuracy 15 to 22 Hz ±0.5% rdg
    40 Hz to 70 Hz ±0.5% rdg
    15 Hz to 1000 Hz ±1% rdg
    Current range 10 A to 1400 A rms
    Voltage range 1 V to 825 V rms
    Scope function
    Current measurement Range 10 A / 20 A / 40 A / 100 A / 200 A / 400 A / 1000 A / 2000 A
    Resolution 1 A in 40 A
    10 A in 400 A
    50 A in 2000 A
    Accuracy ±3% rdg ±1 pixel
    Maximum overload 10,000 A
    Voltage measurement Range 4 V / 10 V / 20 V / 40 V / 100 V / 200 V / 400 V / 1000 V
    Resolution 100 mV in 4 V
    1 V in 40 V
    10 V in 400 V
    31.25 V in 1000 V
    Accuracy ±2% rdg ±1 pixel
    Maximum overload 1000 V rms
    Frequency range DC and 15 Hz to 600 Hz
    Time base 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms/div
    Refresh rate 0.5 seconds
    Maximum sampling rate 15.625 kHz
    Inrush current function
    Ranges 40 A, 400 A, and 2000 A
    Resolution 10 mA in 40 A range
    100 mA in 400 A range
    1 A in 2000 A range
    Accuracy I > 10 A ±5% rdg ±1 pixel
    I < 10 A ±0.5 A
    All measurements DC and 15 Hz to 1 kHz
    Maximum overload Maximum overload 10,000 A or rms x frequency < 400,000
    Amps rms is a true-rms measurement (AC + DC)
    Capture time 1 s, 3 s, 10 s, 30 s, 100 s, and 300 s
    Maximum sampling rate 15.625 kHz
    Interface
    USB Interface to a PC Power Log software for download, analysis and reporting
    345 Upgrade Utility for installing a new firmware version
    Logging Memory
    Logging areas Three areas that can be used individually or combined into one large area
    Averaging periods 1 s, 2 s, 5 s, 10 s, 30 s, 1 min, 5 min, 10 min, 15 min, and custom
    Logging Times
    Volts and current mode Average time Logging time (1 area)
    1 s 1 h 49 m
    2 s 3 h 38 m
    5 s 9 h 6 m
    10 s 18 h 12 m
    30 s 2 d 6 h 36 m
    1 min 4 d 13 h 12 m
    5 min 22 d 18 h 0 m
    10 min 45 d 12 h 0 m
    15 min 68 d 6 h 0 m
    Logging time (3 areas)
    1 s 5 h 12 m
    2 s 10 h 24 m
    5 s 1 d 2 h 00 m
    10 s 2 d 4 h 00 m
    30 s 6 d 12 h 1 m
    1 min 13 d 0 h 12 m
    5 min 65 d 0 h 15 m
    10 min 130 d 0 h 30 m
    15 min 195 d 0 h 45 m
    V and A harmonics mode Average time Logging time (1 area)
    1 s 0 h 34 m
    2 s 1 h 8 m
    5 s 2 h 52 m
    10 s 5 h 44 m
    30 s 17 h 13 m
    1 m 1 d 10 h 26 m
    5 m 7 d 4 h 10 m
    10 m 14 d 8 h 20 m
    15 m 21 d 12 h 30 m
    Logging time (3 areas)
    1 s 1 h 38 m
    2 s 3 h 16 m
    5 s 8 h 11 m
    10 s 16 h 23 m
    30 s 2 d 1 h 11 m
    1 m 4 d 2 h 23 m
    5 m 20 d 11 h 25 m
    10 m 81 d 0 h 50 m
    15 m 121 d 13 h 15 m
    Single- and three-phase power mode Average time Logging time (1 area)
    1 s 1 h 40 m
    2 s 3 h 21 m
    5 s 8 h 22 m
    10 s 16 h 45 m
    30 s 2 d 2 h 17 m
    1 m 4 d 4 h 35 m
    5 m 20 d 22 h 55 m
    10 m 41 d 21 h 50 m
    15 m 62 d 20 h 45 m
    Logging time (3 areas)
    1 s 4 h 47 m
    2 s 9 h 34 m
    5 s 23 h 57 m
    10 s 1 d 23 h 54 m
    30 s 5 d 23 h 25 m
    1 m 11 d 23 h 25 m
    5 m 59 d 21 h 5 m
    10 m 119 d 18 h 10 m
    15 m 179 d 15 h 15 m

Videó

Specifikáció

Letölthető termék információ: Fluke 345

Ajánlatkérés

Célunk, hogy minél egyszerűbbé tegyük  az Ön számára az ajánlatkérést.

Kérjük, töltse ki az alábbi űrlapot és küldje el.

Kollégáink hamarosan jelentkezni fognak az ajánlattal.

Ajánlatkérés

Telefonos visszahívás kérése

Célunk, hogy minél egyszerűbbé tegyük  az Ön számára a termékeinkkel kapcsolatos információhoz jutást.

Kérjük, töltse ki az alábbi űrlapot és küldje el.

Kollégáink hamarosan jelentkezni fognak, hogy megválaszolják kérdését.

Telefonos visszahívás