& MSOInput channels 2 channels, BNC single-ended 4 channels, BNC single-ended Bandwidth
(−3 dB)50 MHz 70 MHz 100 MHz 200 MHz 50 MHz 70 MHz 100 MHz 200 MHz Rise time (calculated) 7.0 ns 5.0 ns 3.5 ns 1.75 ns 7.0 ns 5.0 ns 3.5 ns 1.75 ns Hardware bandwidth limiter Switchable, 20 MHz Vertical resolution 8 bits Input ranges ±20 mV to ±20 V full scale in 10 ranges Input sensitivity 4 mV/div to 4 V/div in 10 vertical divisions Input coupling AC / DC, programmable Input characteristics 1 MΩ ±1%, in parallel with 14 pF ±1 pF DC accuracy ±3% of full scale ±200 μV Analog offset range
(vertical position adjust)±250 mV (20 mV, 50 mV, 100 mV, 200 mV ranges)
±2.5 V (500 mV, 1 V, 2 V ranges)
±20 V (5 V, 10 V, 20 V ranges)Offset adjust accuracy ±1% of offset setting, additional to DC accuracy Overvoltage protection ±100 V (DC + AC peak) Oscilloscope — vertical (digital inputs, MSOs only) Input channels 16 channels (2 ports of 8 channels each) Input connectors 2.54 mm pitch, 10 x 2 way connector Maximum input frequency 100 MHz (200 Mb/s) Minimum detectable pulse width 5 ns Channel-to-channel skew 2 ns, typical Minimum input slew rate 10 V/µs Input impedance 200 kΩ ±2% ∥ 8 pF ±2 pF Input dynamic range ±20 V Overvoltage protection ±50 V Digital threshold range ±5 V Threshold grouping Two independent threshold controls: D0…D7 and D8…D15 Threshold selection TTL, CMOS, ECL, PECL, user-defined Threshold accuracy < ±350 mV (inclusive of hysteresis) Hysteresis < ±250 mV Minimum input voltage swing 500 mV pk-pk Oscilloscope — horizontal PicoScope Model 3203D
& MSO3204D
& MSO3205D
& MSO3206D
& MSO3403D
& MSO3404D
& MSO3405D
& MSO3406D
& MSOMaximum sampling rate (real-time) 1 GS/s (1 analog channel)
500 MS/s (up to 2 analog channels or digital ports*)
250 MS/s (up to 4 analog channels or digital ports*)
125 MS/s (all other combinations)Maximum effective sampling rate (repetitive signals)** 2.5 GS/s 5 GS/s 10 GS/s 2.5 GS/s 5 GS/s 10 GS/s Maximum sampling rate
(continuous streaming mode)17 MS/s in PicoScope software
125 MS/s when using the supplied SDK (PC-dependent)Maximum capture rate 100,000 waveforms/second (PC-dependent) Timebase ranges 1 ns/div to 5000 s/div 500 ps/div to 5000 s/div 1 ns/div to 5000 s/div 500 ps/div to 5000 s/div Buffer memory 64 MS 128 MS 256 MS 512 MS 64 MS 128 MS 256 MS 512 MS Buffer memory (streaming) 100 MS in PicoScope software.
Up to available PC memory when using supplied SDK.Maximum buffer segments 10 000 in PicoScope software 130 000 using SDK 250 000 using SDK 500 000 using SDK 1 000 000 using SDK 130 000 using SDK 250 000 using SDK 500 000 using SDK 1 000 000 using SDK Timebase accuracy ±50 ppm ±2 ppm ±50 ppm ±2 ppm Timebase drift per year ±5 ppm ±1 ppm ±5 ppm ±1 ppm Sample jitter 3 ps RMS typical ADC sampling Simultaneous on all enabled channels * A digital port consists of 8 digital channels, D0–7 or D8–15
** ETS mode on channel A onlyDynamic performance (typical) PicoScope Model 3203D & MSO 3204D & MSO 3205D & MSO 3206D & MSO 3403D & MSO 3404D & MSO 3405D & MSO 3406D & MSO Crosstalk Better than 400:1 up to full bandwidth (equal voltage ranges) Harmonic distortion < −50 dB at 100 kHz full scale input SFDR 52 dB typical at 100 kHz full scale input
(except ±20 mV range: 44 dB)Noise 110 µV RMS 160 µV RMS 110 µV RMS 160 µV RMS (typical, on ±20 mV range) Bandwidth flatness +0.3 dB, −3 dB from DC to full bandwidth, typical Triggering – general Source Analog channels, EXT trigger (not MSOs), digital channels (MSOs only) Trigger modes None, auto, repeat, single, rapid (segmented memory) Maximum pre–trigger capture Up to 100% of capture size Maximum post–trigger delay Up to 4 billion samples (selectable in 1 sample steps) Trigger rearm time < 0.7 µs at 1 GS/s sampling rate Maximum trigger rate Up to 10,000 waveforms in a 6 ms burst at 1 GS/s sampling rate, typical Triggering – analog channels Advanced triggers Edge, window, pulse width, window pulse width, dropout, window dropout, interval, logic, runt pulse Trigger types (ETS mode) Rising edge, falling edge (Ch A only) Trigger sensitivity Digital triggering provides 1 LSB accuracy up to full bandwidth of scope Trigger sensitivity (ETS mode) 10 mV p-p typical (at full bandwidth) Triggering – EXT trigger input, not MSO models Connector type Front panel BNC Advanced triggers Edge, pulse width, dropout, interval, logic Input characteristics 1 MΩ || 14 pF Bandwidth 50 MHz 70 MHz 100 MHz 200 MHz 50 MHz 70 MHz 100 MHz 200 MHz Threshold range ±5 V Coupling DC Overvoltage protection ±100 V (DC + AC peak) Triggering – digital channels, MSO models only Source D0 to D15 Trigger types Pattern, edge, combined pattern and edge, pulse width, dropout, interval, logic Function generator Standard output signals Sine, square, triangle, DC voltage, ramp, sinc, Gaussian, half-sine, white noise, PRBS Standard signal frequency DC to 1 MHz Sweep modes Up, down, dual with selectable start / stop frequencies and increments Triggering Free-run, or from 1 to 1 billion counted waveform cycles or frequency sweeps. Triggered from scope trigger or manually. Output frequency accuracy As oscilloscope Output frequency resolution < 0.01 Hz Output voltage range ±2 V Output voltage adjustment Signal amplitude and offset adjustable in approximate 1 mV steps within overall ±2 V range Amplitude flatness < 0.5 dB to 1 MHz typical DC accuracy ±1% of full scale SFDR > 60 dB 10 kHz full scale sine wave Output impedance 600 Ω Connector type Front panel BNC (non-MSO models)
Rear panel BNC (MSO models)Overvoltage protection ±20 V Arbitrary waveform generator Update rate 20 MS/s Buffer size 32 kS Resolution 12 bits (output step size approximately 1 mV) Bandwidth > 1 MHz Rise time (10% to 90%) < 120 ns Other AWG specifications as function generator
Probe compensation output Impedance 600 Ω Frequency 1 kHz Level 2 V pk-pk, typical Spectrum analyzer Frequency range DC to maximum bandwidth of scope Display modes Magnitude, peak hold, average X axis Linear or log 10 Y axis Logarithmic (dbV, dBu, dBm, arbitrary) or linear (volts) Windowing functions Rectangular, Gaussian, triangular, Blackman, Blackman–Harris, Hamming, Hann, flat-top Number of FFT points Selectable from 128 to 1 million in powers of 2 Math channels General functions −x, x+y, x−y, x*y, x/y, x^y, sqrt, exp, ln, log, abs, norm, sign, sin, cos, tan, arcsin, arccos, arctan, sinh, cosh, tanh, derivative, integral, delay Filter functions Low pass, high pass, band stop, band pass Graphing functions Frequency, duty cycle Multi-waveform functions Min, max, average, peak Operands All analog and digital input channels, reference waveforms, time, constants, pi Automatic measurements (analog channels only) Oscilloscope mode AC RMS, true RMS, cycle time, DC average, duty cycle, falling rate, fall time, frequency, high pulse width, low pulse width, maximum, minimum, peak to peak, rise time, rising rate Spectrum mode Frequency at peak, amplitude at peak, average amplitude at peak, total power, THD %, THD dB, THD+N, SFDR, SINAD, SNR, IMD Statistics Minimum, maximum, average, standard deviation Serial decoding Protocols 1-Wire, ARINC 429, CAN, DCC, DMX512, Ethernet (10BaseT, 100BaseTX), FlexRay, I²C, I²S, LIN, PS/2, SENT, SPI, UART/RS-232, USB 1.0 Mask limit testing Statistics Pass/fail, failure count, total count Display Interpolation Linear or sin(x)/x Persistence modes Digital color, analog intensity, fast, custom Miscellaneous Output file formats BMP, CSV, GIF, JPEG, MATLAB 4, PDF, PNG, PSDATA, PSSETTINGS, TXT Output functions Copy to clipboard, print Software Windows software PicoScope for Windows
PicoSDK Software development kit (SDK)
Windows 7, 8 or 10 recommended (read more)macOS software PicoScope for macOS (beta: feature list)
Software development kit (SDK)
OS versions: see release notesLinux software PicoScope for Linux (beta: feature list)
Software development kit (SDK)
See Linux Software & Drivers for details of supported distributionsLanguages Chinese (simplified), Chinese (traditional), Czech, Danish, Dutch, English, Finnish, French, German, Greek, Hungarian, Italian, Japanese, Korean, Norwegian, Polish, Portuguese, Romanian, Russian, Spanish, Swedish, Turkish Physical specifications Dimensions 190 mm x 170 mm x 40 mm (including connectors) Weight < 0.5 kg Temperature range Operating: 0 °C to 40 °C (15 °C to 30 °C for stated accuracy).
Storage: –20 °C to 60 °CHumidity range Operating: 5% RH to 80% RH non-condensing.
Storage: 5% RH to 95% RH non-condensingAltitude range Up to 2000 m Pollution degree 2 General Package contents PicoScope 3000D Series oscilloscope
2 or 4 switchable 10:1/1:1 oscilloscope probes
Quick Start Guide
USB 3.0 cable
AC power adaptor (4-channel models only)
TA136 digital cable (MSOs only)
2 × TA139 pack of 10 logic test clips (MSOs only)PC connectivity USB 3.0 SuperSpeed (USB 2.0 compatible) Power requirements Powered from a single USB 3.0 port or two USB 2.0 ports.
4-channel models: AC adaptor included for use with USB ports that supply less than 1200 mASafety approvals Designed to EN 61010-1:2010 EMC approvals Tested to EN 61326-1:2006 and FCC Part 15 Subpart B Environmental approvals RoHS and WEEE compliant Warranty 5 years