Leírás
-
Oscilloscope — vertical Input channels 8 Bandwidth (−3 dB) 20 MHz (50 mV to 50 V ranges)
10 MHz (10 mV and 20 mV ranges)Rise time (calculated) 17.5 ns (50 mV to 50 V ranges)
35.0 ns (10 mV and 20 mV ranges)Input type BNC, 20 mm spacing Vertical resolution 12 bits Software-enhanced vertical resolution Up to 16 bits Input sensitivity 2 mV/div to 10 V/div (10 vertical divisions) Input ranges ±10 mV to ±50 V full scale, in 12 ranges Input coupling Software-selectable AC / DC Input characteristics 1 MΩ ∥ 19 pF DC accuracy ±1% of full scale ±300 μV Analog offset range (vertical position adjustment) ±250 mV (10 mV to 500 mV ranges)
±2.5 V (1 V to 5 V ranges)
±25 V (10 V to 50 V ranges)Overvoltage protection ±100 V (DC + AC peak) Oscilloscope — horizontal Maximum sampling rate (real-time) 80 MS/s (1 to 4 channels in use)
40 MS/s (5 to 8 channels in use)Maximum sampling rate (continuous streaming mode) 20 MS/s using PicoScope 6 software
80 MS/s per channel using supplied API, 160 MS/s total across all channels (PC-dependent)Timebase ranges 20 ns/div to 5000 s/div Buffer memory 256 MS shared between active channels Streaming buffer memory (PicoScope) 100 MS Streaming buffer memory (SDK) Up to available PC memory Maximum buffer segments (PicoScope) 10,000 Maximum waveforms per second 100,000 (PC-dependent) Timebase accuracy ±20 ppm (+5 ppm/year) Sample jitter 25 ps RMS typical Dynamic performance (typical) Crosstalk 20 000:1, DC to 20 MHz Harmonic distortion < −60 dB, 10 mV range
< −70 dB, 20 mV and higher rangesSFDR > 60 dB, 20 mV and 10 mV ranges
> 70 dB, 50 mV and higher rangesNoise 45 μV RMS on 10 mV range Bandwidth flatness DC to full bandwidth (+0.2 dB, −3 dB) Pulse response < 1% overshoot ADC ENOB 11.3 bits Triggering Source Channels A to H Trigger modes Free run, auto, repeat, single, rapid (segmented memory) Trigger types Edge with adjustable hysteresis, pulse width, window, window pulse width, dropout, window dropout, interval, logic level, runt pulse Trigger sensitivity Digital triggering provides 1 LSB accuracy up to full bandwidth Maximum pre-trigger capture Up to 100% of capture size Maximum post-trigger delay Up to 4 billion samples Trigger rearm time < 3 μs on fastest timebase Maximum trigger rate Up to 10 000 waveforms in a 30 ms burst Trigger level All trigger levels, window levels and hysteresis values settable with 1 LSB resolution across input range Pulse width trigger Settable with 1 sample resolution from 1 sample (minimum 12.5 ns) up to 4 billion sample intervals Function generator Standard output signals Sine, square, triangle, DC voltage, ramp, sinc, Gaussian, half-sine, white noise, PRBS Standard signal frequency DC to 1 MHz Sweep modes Up, down, dual Triggering Can trigger a counted number of waveform cycles or sweeps (up to 1 billion)
from the scope trigger or manually from software.Frequency accuracy ±20 ppm Frequency resolution < 20 mHz Voltage range ±2 V Amplitude and offset adjustment Signal amplitude and offset within ± 2V range. Adjustable in approx 300 μV steps. Amplitude flatness < 0.5 dB to 1 MHz typical DC accuracy ±1% of full scale SFDR 87 dB typical Output characteristics Rear-panel BNC, 600 Ω output impedance Overvoltage protection ±10 V Arbitrary Waveform Generator Update rate 80 MS/s Buffer size 16 kS Resolution 14 bits Bandwidth 1 MHz Rise time (10% to 90%) 150 ns Spectrum analyzer Frequency range DC to 20 MHz Display modes Magnitude, average, peak hold Windowing functions Rectangular, Gaussian, triangular, Blackman, Blackman-Harris, Hamming, Hann, flat-top Number of FFT points Selectable from 128 up to 1 million in powers of 2 Scale / units X axis : linear or log 10
Y axis : logarithmic (dbV, dBu, dBm, arbitrary) or linear (volts)Math channels General functions −x, x+y, x−y, x*y, x/y, x^y, sqrt, exp, ln, log, abs, norm, sign, sin, cos, tan, arcsin, arccos, arctan, sinh, cosh, tanh, derivative, integral, delay Filter functions Lowpass, highpass, bandstop, bandpass Graphing functions Frequency, duty cycle Multi-waveform functions Min, max, average, peak Operands Input channels, reference waveforms, time, constants, pi Automatic measurements Scope mode AC RMS, true RMS, cycle time, DC average, duty cycle, falling rate, fall time, frequency, high pulse width, low pulse width, maximum, minimum, peak to peak, rise time, rising rate. Spectrum mode Frequency at peak, amplitude at peak, average amplitude at peak, total power, THD %, THD dB, THD+N, SFDR, SINAD, SNR, IMD Statistics Minimum, maximum, average and standard deviation Serial decoding Protocols 1-Wire, ARINC 429, CAN, DCC, DMX512, Ethernet (10Base-T), FlexRay, I²C, I²S, LIN, PS/2, SENT, SPI, UART/RS-232, USB 1.0 Inputs All input channels with any mixture of protocols Mask limit testing Mask generation Auto generate from captured waveform, manual drawing, manual coordinate entry Actions Highlight on screen, select in buffer overview, activate alarm Statistics Pass/fail, failure count, total count Alarms Initiating events Capture, buffer full, mask fail Alarm actions Beep, play sound, stop/restart capture, run executable, save current buffer/all buffers, trigger signal generator Display Interpolation Linear or sin(x)/x Persistence modes Digital color, analog intensity, fast, custom Data export Output file formats BMP, CSV, GIF, JPG, MATLAB 4, PDF, PNG, PicoScope data, PicoScope settings, TXT Output functions Copy to clipboard, print Environmental Temperature range (operating) 0 °C to 45 °C Temperature range (stated accuracy) 20 °C to 30 °C Temperature range (storage) –20 °C to +60 °C Humidity range (operating) 5% to 80% RH non-condensing Humidity range (storage) 5% to 95% RH non-condensing Physical properties Dimensions 190 x 170 x 40 mm Weight < 0.55 kg Software Windows software PicoScope for Windows
Software development kit (SDK)
Windows 7, 8 or 10 recommended (read more)macOS software PicoScope for macOS (beta: feature list)
Software development kit (SDK)
OS versions: see release notesLinux software PicoScope for Linux (beta: feature list)
Software development kit (SDK)
See Linux Software & Drivers for details of supported distributionsLanguages Chinese (simplified), Chinese (traditional), Czech, Danish, Dutch, English, Finnish, French, German, Greek, Hungarian, Italian, Japanese, Korean, Norwegian, Polish, Portuguese, Romanian, Russian, Spanish, Swedish, Turkish General What’s in the box? PicoScope 4824 high-resolution oscilloscope
USB 3.0 cable
USB Oscilloscope Quick Start GuidePC connectivity SuperSpeed USB 3.0 (USB 1.1 and USB 2.0 compatible) Power requirements Powered from single USB 3.0 port or two USB 2.0 ports Safety approvals LVD compliant EMC approvals Tested to meet EN61326-1:2006 and FCC Part 15 Subpart B Environmental approvals RoHS and WEEE compliant Total satisfaction guarantee In the event that this product does not fully meet your requirements you can return it for an exchange or refund. To claim, the product must be returned in good condition within 14 days. Warranty 5 years